{"id":2906,"date":"2026-10-09T21:02:34","date_gmt":"2026-10-09T19:02:34","guid":{"rendered":"https:\/\/inductance.be\/?p=2906"},"modified":"2026-06-29T21:05:39","modified_gmt":"2026-06-29T19:05:39","slug":"controle-dune-installation-gaz-par-un-organisme-agree","status":"publish","type":"post","link":"https:\/\/inductance.be\/nl\/controle-dune-installation-gaz-par-un-organisme-agree\/","title":{"rendered":"Le contr\u00f4le d&rsquo;une installation gaz par un organisme agr\u00e9\u00e9"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2906\" class=\"elementor elementor-2906\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1563f8d0 e-flex e-con-boxed e-con e-parent\" data-id=\"1563f8d0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5075c7a9 elementor-widget elementor-widget-text-editor\" data-id=\"5075c7a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Le contr\u00f4le d&rsquo;une installation gaz par un organisme agr\u00e9\u00e9\u00a0<\/strong><strong style=\"font-size: 1rem; font-style: inherit;\">ne doit pas \u00eatre consid\u00e9r\u00e9 comme une sanction, mais comme la derni\u00e8re \u00e9tape permettant de garantir la s\u00e9curit\u00e9 de l&rsquo;installation avant sa mise en service.<\/strong><\/p>\n<p><strong>7.1 Quel est le r\u00f4le d&rsquo;un <a href=\"https:\/\/elgacert.be\/controleorganismes\/?lang=fr\" target=\"_blank\" rel=\"noopener\">organisme agr\u00e9\u00e9<\/a> ?<\/strong><\/p>\n<p>Lorsqu&rsquo;une nouvelle installation est r\u00e9alis\u00e9e ou qu&rsquo;une installation existante est modifi\u00e9e de mani\u00e8re importante, un contr\u00f4le peut \u00eatre n\u00e9cessaire avant sa mise en service.<\/p>\n<p>Ce contr\u00f4le est r\u00e9alis\u00e9 par un organisme agr\u00e9\u00e9 ind\u00e9pendant.<\/p>\n<p>Sa mission est simple :<\/p>\n<p><strong>v\u00e9rifier que l&rsquo;installation r\u00e9pond aux exigences de s\u00e9curit\u00e9 applicables au moment de son inspection.<\/strong><\/p>\n<p>Le contr\u00f4leur ne r\u00e9alise aucune r\u00e9paration.<\/p>\n<p>Il n&rsquo;intervient pas dans la conception de l&rsquo;installation.<\/p>\n<p>Il constate objectivement son \u00e9tat au moment de sa visite.<\/p>\n<p>Cette ind\u00e9pendance constitue l&rsquo;une des garanties essentielles de la qualit\u00e9 du contr\u00f4le.<\/p>\n<p><strong>Les objectifs du contr\u00f4le<\/strong><\/p>\n<p>Le contr\u00f4le poursuit plusieurs objectifs.<\/p>\n<p>Il permet notamment de :<\/p>\n<ul>\n<li>v\u00e9rifier la s\u00e9curit\u00e9 de l&rsquo;installation ;<\/li>\n<li>confirmer l&rsquo;\u00e9tanch\u00e9it\u00e9 du r\u00e9seau ;<\/li>\n<li>contr\u00f4ler les appareils install\u00e9s ;<\/li>\n<li>examiner la ventilation des locaux ;<\/li>\n<li>v\u00e9rifier les conduits d&rsquo;\u00e9vacuation ;<\/li>\n<li>d\u00e9tecter les anomalies susceptibles de pr\u00e9senter un danger.<\/li>\n<\/ul>\n<p>L&rsquo;objectif n&rsquo;est pas de rechercher des erreurs mineures, mais de s&rsquo;assurer que l&rsquo;installation peut \u00eatre utilis\u00e9e dans de bonnes conditions de s\u00e9curit\u00e9.<\/p>\n<p><strong>7.2 Avant l&rsquo;arriv\u00e9e du contr\u00f4leur<\/strong><\/p>\n<p>Une bonne pr\u00e9paration facilite consid\u00e9rablement le contr\u00f4le.<\/p>\n<p>Avant le rendez-vous, il est conseill\u00e9 de v\u00e9rifier plusieurs points.<\/p>\n<p><strong>Les documents<\/strong><\/p>\n<p>Pr\u00e9parez notamment :<\/p>\n<ul>\n<li>les notices techniques des appareils ;<\/li>\n<li>les certificats des conduits lorsque cela est n\u00e9cessaire ;<\/li>\n<li>les plans \u00e9ventuels de l&rsquo;installation ;<\/li>\n<li>les attestations des essais r\u00e9alis\u00e9s.<\/li>\n<\/ul>\n<p>Disposer de ces documents permet souvent de r\u00e9pondre rapidement aux questions du contr\u00f4leur.<\/p>\n<p><strong>L&rsquo;accessibilit\u00e9<\/strong><\/p>\n<p>Le contr\u00f4leur doit pouvoir acc\u00e9der facilement :<\/p>\n<ul>\n<li>au compteur ;<\/li>\n<li>aux robinets de coupure ;<\/li>\n<li>\u00e0 la chaudi\u00e8re ;<\/li>\n<li>aux conduits ;<\/li>\n<li>aux diff\u00e9rents appareils.<\/li>\n<\/ul>\n<p>Une installation inaccessible ne peut pas \u00eatre correctement v\u00e9rifi\u00e9e.<\/p>\n<p><strong>Les essais pr\u00e9alables<\/strong><\/p>\n<p>Avant le contr\u00f4le, l&rsquo;installateur devrait d\u00e9j\u00e0 avoir v\u00e9rifi\u00e9 :<\/p>\n<ul>\n<li>l&rsquo;absence de fuite ;<\/li>\n<li>le fonctionnement des appareils ;<\/li>\n<li>la stabilit\u00e9 de la pression ;<\/li>\n<li>la conformit\u00e9 des raccordements.<\/li>\n<\/ul>\n<p>Cette pr\u00e9paration r\u00e9duit fortement le risque de remarques lors de l&rsquo;inspection.<\/p>\n<p><strong>Conseil Inductance<\/strong><\/p>\n<p>Ne programmez jamais un contr\u00f4le alors que le chantier est encore en cours.<\/p>\n<p>Une installation inachev\u00e9e entra\u00eene souvent une contre-visite qui pourrait \u00eatre \u00e9vit\u00e9e.<\/p>\n<p><strong>7.3 D\u00e9roulement du contr\u00f4le<\/strong><\/p>\n<p>Chaque organisme agr\u00e9\u00e9 applique une m\u00e9thode rigoureuse.<\/p>\n<p>M\u00eame si l&rsquo;ordre des op\u00e9rations peut varier l\u00e9g\u00e8rement, les principales \u00e9tapes restent les m\u00eames.<\/p>\n<p><strong>\u00c9tape 1 \u2013 Identification<\/strong><\/p>\n<p>Le contr\u00f4leur identifie :<\/p>\n<ul>\n<li>l&rsquo;adresse du chantier ;<\/li>\n<li>le propri\u00e9taire ;<\/li>\n<li>l&rsquo;installateur ;<\/li>\n<li>les appareils pr\u00e9sents.<\/li>\n<\/ul>\n<p>Cette premi\u00e8re \u00e9tape permet de v\u00e9rifier que le rapport correspondra bien \u00e0 l&rsquo;installation inspect\u00e9e.<\/p>\n<p><strong>\u00c9tape 2 \u2013 Inspection visuelle<\/strong><\/p>\n<p>Le contr\u00f4leur examine ensuite l&rsquo;ensemble du r\u00e9seau.<\/p>\n<p>Il v\u00e9rifie notamment :<\/p>\n<ul>\n<li>les mat\u00e9riaux utilis\u00e9s ;<\/li>\n<li>le cheminement des conduites ;<\/li>\n<li>les fixations ;<\/li>\n<li>les protections m\u00e9caniques ;<\/li>\n<li>les robinets ;<\/li>\n<li>les raccords.<\/li>\n<\/ul>\n<p>Cette inspection permet d\u00e9j\u00e0 d&rsquo;identifier de nombreuses anomalies.<\/p>\n<p><strong>\u00c9tape 3 \u2013 V\u00e9rification des appareils<\/strong><\/p>\n<p>Chaque appareil est examin\u00e9.<\/p>\n<p>Le contr\u00f4leur v\u00e9rifie :<\/p>\n<ul>\n<li>son type ;<\/li>\n<li>son implantation ;<\/li>\n<li>son accessibilit\u00e9 ;<\/li>\n<li>son raccordement ;<\/li>\n<li>sa plaque signal\u00e9tique.<\/li>\n<\/ul>\n<p>Les prescriptions du fabricant constituent une r\u00e9f\u00e9rence essentielle.<\/p>\n<p><strong>\u00c9tape 4 \u2013 Les conduits<\/strong><\/p>\n<p>Le syst\u00e8me d&rsquo;\u00e9vacuation fait ensuite l&rsquo;objet d&rsquo;un contr\u00f4le.<\/p>\n<p>Les principaux points observ\u00e9s sont :<\/p>\n<ul>\n<li>la compatibilit\u00e9 avec l&rsquo;appareil ;<\/li>\n<li>le mat\u00e9riau utilis\u00e9 ;<\/li>\n<li>les assemblages ;<\/li>\n<li>les fixations ;<\/li>\n<li>les sorties en fa\u00e7ade ou en toiture.<\/li>\n<\/ul>\n<p><strong>\u00c9tape 5 \u2013 La ventilation<\/strong><\/p>\n<p>Lorsque le type d&rsquo;appareil l&rsquo;exige, le local doit disposer d&rsquo;une ventilation adapt\u00e9e.<\/p>\n<p>Le contr\u00f4leur v\u00e9rifie :<\/p>\n<ul>\n<li>les amen\u00e9es d&rsquo;air ;<\/li>\n<li>les \u00e9vacuations \u00e9ventuelles ;<\/li>\n<li>l&rsquo;absence d&rsquo;obstruction.<\/li>\n<\/ul>\n<p>Une simple grille condamn\u00e9e peut suffire \u00e0 rendre l&rsquo;installation non conforme.<\/p>\n<p><strong>\u00c9tape 6 \u2013 Essais<\/strong><\/p>\n<p>Selon le type d&rsquo;installation, diff\u00e9rents essais peuvent \u00eatre r\u00e9alis\u00e9s.<\/p>\n<p>Ils permettent notamment de v\u00e9rifier :<\/p>\n<ul>\n<li>l&rsquo;\u00e9tanch\u00e9it\u00e9 ;<\/li>\n<li>le fonctionnement g\u00e9n\u00e9ral ;<\/li>\n<li>certains param\u00e8tres techniques.<\/li>\n<\/ul>\n<p>Ces essais compl\u00e8tent l&rsquo;inspection visuelle.<\/p>\n<p><strong>7.4 Les instruments utilis\u00e9s<\/strong><\/p>\n<p>Le contr\u00f4leur dispose de plusieurs \u00e9quipements sp\u00e9cialis\u00e9s.<\/p>\n<p>Parmi les plus courants figurent :<\/p>\n<ul>\n<li>un manom\u00e8tre de pr\u00e9cision ;<\/li>\n<li>un d\u00e9tecteur de fuite ;<\/li>\n<li>un appareil de mesure de pression ;<\/li>\n<li>un analyseur de combustion (selon les cas) ;<\/li>\n<li>diff\u00e9rents instruments de contr\u00f4le.<\/li>\n<\/ul>\n<p>Ces appareils permettent d&rsquo;obtenir des mesures fiables et reproductibles.<\/p>\n<p><strong>Tableau pratique<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<td>\n<p><strong>V\u00e9rification<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Pourquoi ?<\/strong><\/p>\n<\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\n<p>Tuyauteries<\/p>\n<\/td>\n<td>\n<p>D\u00e9tecter les anomalies de pose<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Raccords<\/p>\n<\/td>\n<td>\n<p>V\u00e9rifier leur conformit\u00e9<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Robinets<\/p>\n<\/td>\n<td>\n<p>Contr\u00f4ler leur accessibilit\u00e9<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Appareils<\/p>\n<\/td>\n<td>\n<p>V\u00e9rifier leur implantation<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Ventilation<\/p>\n<\/td>\n<td>\n<p>Garantir la combustion<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conduits<\/p>\n<\/td>\n<td>\n<p>Assurer l&rsquo;\u00e9vacuation des fum\u00e9es<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>7.5 Le rapport de contr\u00f4le<\/strong><\/p>\n<p>\u00c0 la fin de son intervention, le contr\u00f4leur r\u00e9dige un rapport.<\/p>\n<p>Ce document reprend notamment :<\/p>\n<ul>\n<li>l&rsquo;identification de l&rsquo;installation ;<\/li>\n<li>les v\u00e9rifications r\u00e9alis\u00e9es ;<\/li>\n<li>les remarques \u00e9ventuelles ;<\/li>\n<li>les non-conformit\u00e9s constat\u00e9es ;<\/li>\n<li>la conclusion du contr\u00f4le.<\/li>\n<\/ul>\n<p>Il constitue la trace officielle de l&rsquo;inspection.<\/p>\n<p>Le propri\u00e9taire doit le conserver avec les autres documents de l&rsquo;installation.<\/p>\n<p><strong>Les diff\u00e9rents types de remarques<\/strong><\/p>\n<p>Toutes les observations n&rsquo;ont pas la m\u00eame importance.<\/p>\n<p>Le rapport peut comprendre :<\/p>\n<ul>\n<li>des observations ;<\/li>\n<li>des recommandations ;<\/li>\n<li>des non-conformit\u00e9s.<\/li>\n<\/ul>\n<p>Chaque remarque doit \u00eatre analys\u00e9e afin de d\u00e9terminer les \u00e9ventuelles actions correctives \u00e0 entreprendre.<\/p>\n<p><strong>7.6 Les contre-visites<\/strong><\/p>\n<p>Lorsque des non-conformit\u00e9s importantes sont constat\u00e9es, une nouvelle visite peut \u00eatre n\u00e9cessaire apr\u00e8s les corrections.<\/p>\n<p>Cette seconde inspection permet de v\u00e9rifier que les anomalies ont bien \u00e9t\u00e9 supprim\u00e9es.<\/p>\n<p>Une bonne pr\u00e9paration du chantier permet g\u00e9n\u00e9ralement d&rsquo;\u00e9viter cette situation.<\/p>\n<p><strong>Cas pratique<\/strong><\/p>\n<p>Une chaudi\u00e8re \u00e0 condensation vient d&rsquo;\u00eatre remplac\u00e9e.<\/p>\n<p>L&rsquo;installation semble termin\u00e9e.<\/p>\n<p>Lors du contr\u00f4le, une seule anomalie est constat\u00e9e.<\/p>\n<p>Le robinet de coupure est situ\u00e9 derri\u00e8re un meuble r\u00e9cemment install\u00e9.<\/p>\n<p>La chaudi\u00e8re fonctionne parfaitement.<\/p>\n<p>Le conduit est conforme.<\/p>\n<p>L&rsquo;installation est \u00e9tanche.<\/p>\n<p>Pourtant, l&rsquo;accessibilit\u00e9 du robinet n&rsquo;est plus assur\u00e9e.<\/p>\n<p>Apr\u00e8s d\u00e9placement du meuble, une contre-visite rapide permet de cl\u00f4turer le dossier.<\/p>\n<p>Cet exemple montre qu&rsquo;une non-conformit\u00e9 ne concerne pas toujours un probl\u00e8me technique complexe.<\/p>\n<p><strong>Les erreurs les plus fr\u00e9quemment observ\u00e9es<\/strong><\/p>\n<p>Au fil des ann\u00e9es, les contr\u00f4leurs d&rsquo;Inductance rencontrent r\u00e9guli\u00e8rement :<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/274c.svg\" alt=\"\u274c\" \/> robinet inaccessible ;<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/274c.svg\" alt=\"\u274c\" \/> documentation absente ;<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/274c.svg\" alt=\"\u274c\" \/> ventilation obstru\u00e9e ;<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/274c.svg\" alt=\"\u274c\" \/> mauvais positionnement des conduits ;<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/274c.svg\" alt=\"\u274c\" \/> supports manquants ;<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/274c.svg\" alt=\"\u274c\" \/> protections m\u00e9caniques oubli\u00e9es ;<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/274c.svg\" alt=\"\u274c\" \/> prescriptions du fabricant non respect\u00e9es.<\/p>\n<p>La plupart de ces anomalies sont facilement \u00e9vitables.<\/p>\n<p><strong>Le conseil du contr\u00f4leur Inductance<\/strong><\/p>\n<p>Avant de demander un contr\u00f4le, r\u00e9alisez votre propre inspection.<\/p>\n<p>Parcourez l&rsquo;installation comme si vous \u00e9tiez le contr\u00f4leur.<\/p>\n<p>Posez-vous les questions suivantes :<\/p>\n<ul>\n<li>Est-ce que tout est accessible ?<\/li>\n<li>Les mat\u00e9riaux sont-ils adapt\u00e9s ?<\/li>\n<li>Les conduits sont-ils correctement assembl\u00e9s ?<\/li>\n<li>Les notices ont-elles \u00e9t\u00e9 respect\u00e9es ?<\/li>\n<li>Les essais ont-ils \u00e9t\u00e9 r\u00e9alis\u00e9s ?<\/li>\n<\/ul>\n<p>Quelques minutes d&rsquo;autocontr\u00f4le permettent souvent d&rsquo;\u00e9viter une contre-visite.<\/p>\n<p><strong>\u00c0 retenir<\/strong><\/p>\n<p>Un contr\u00f4le r\u00e9ussi repose sur trois \u00e9l\u00e9ments :<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/2714.svg\" alt=\"\u2714\" \/> une installation correctement con\u00e7ue ;<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/2714.svg\" alt=\"\u2714\" \/> une ex\u00e9cution soign\u00e9e ;<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/2714.svg\" alt=\"\u2714\" \/> une pr\u00e9paration compl\u00e8te avant l&rsquo;inspection.<\/p>\n<p>Le r\u00f4le de l&rsquo;organisme agr\u00e9\u00e9 est de confirmer que ces trois conditions sont r\u00e9unies afin de garantir la s\u00e9curit\u00e9 des occupants.<\/p>\n<p><strong>Chapitre suivant<\/strong><\/p>\n<p>Dans le prochain chapitre, nous analyserons <strong>les non-conformit\u00e9s les plus fr\u00e9quemment rencontr\u00e9es sur le terrain<\/strong>.<\/p>\n<p>\u00c0 partir de nombreux exemples inspir\u00e9s de situations r\u00e9elles, nous expliquerons :<\/p>\n<ul>\n<li>pourquoi ces d\u00e9fauts apparaissent ;<\/li>\n<li>quels risques ils pr\u00e9sentent ;<\/li>\n<li>comment les corriger ;<\/li>\n<li>comment les \u00e9viter d\u00e8s la conception.<\/li>\n<\/ul>\n<p>Ce chapitre constituera une v\u00e9ritable aide pratique aussi bien pour les installateurs que pour les particuliers souhaitant pr\u00e9parer efficacement leur installation avant un contr\u00f4le r\u00e9alis\u00e9 par <strong>Inductance<\/strong>.<\/p>\n<p><strong>Chapitre 8<\/strong><\/p>\n<p><strong>Les non-conformit\u00e9s les plus fr\u00e9quemment rencontr\u00e9es lors des contr\u00f4les<\/strong><\/p>\n<p><strong>Plus de 80 % des non-conformit\u00e9s constat\u00e9es lors d&rsquo;un contr\u00f4le pourraient \u00eatre \u00e9vit\u00e9es gr\u00e2ce \u00e0 une meilleure pr\u00e9paration de l&rsquo;installation.<\/strong><\/p>\n<p><strong>Introduction<\/strong><\/p>\n<p>Chaque ann\u00e9e, les contr\u00f4leurs d&rsquo;Inductance inspectent de nombreuses installations au gaz naturel.<\/p>\n<p>Si chaque chantier est diff\u00e9rent, l&rsquo;exp\u00e9rience montre que certaines anomalies reviennent de mani\u00e8re r\u00e9currente.<\/p>\n<p>Ces d\u00e9fauts ne sont g\u00e9n\u00e9ralement pas dus \u00e0 un mat\u00e9riel d\u00e9fectueux.<\/p>\n<p>Ils r\u00e9sultent le plus souvent :<\/p>\n<ul>\n<li>d&rsquo;un manque d&rsquo;information ;<\/li>\n<li>d&rsquo;une mauvaise interpr\u00e9tation des prescriptions ;<\/li>\n<li>d&rsquo;un oubli lors de l&rsquo;installation ;<\/li>\n<li>d&rsquo;une modification r\u00e9alis\u00e9e plusieurs ann\u00e9es apr\u00e8s la mise en service.<\/li>\n<\/ul>\n<p>L&rsquo;objectif de ce chapitre est de pr\u00e9senter les non-conformit\u00e9s les plus fr\u00e9quemment rencontr\u00e9es afin d&rsquo;aider les installateurs et les propri\u00e9taires \u00e0 les \u00e9viter.<\/p>\n<p><strong>8.1 Robinet de coupure inaccessible<\/strong><\/p>\n<p>Il s&rsquo;agit probablement de l&rsquo;une des remarques les plus fr\u00e9quentes.<\/p>\n<p>Apr\u00e8s l&rsquo;installation d&rsquo;une cuisine, d&rsquo;un meuble ou d&rsquo;un am\u00e9nagement int\u00e9rieur, le robinet devient inaccessible.<\/p>\n<p>Pourtant, ce robinet doit toujours pouvoir \u00eatre man\u0153uvr\u00e9 rapidement en cas d&rsquo;urgence.<\/p>\n<p><strong>Pourquoi est-ce important ?<\/strong><\/p>\n<p>En cas de fuite ou d&rsquo;intervention sur un appareil, il doit \u00eatre possible de couper imm\u00e9diatement l&rsquo;alimentation en gaz.<\/p>\n<p>Quelques secondes peuvent faire toute la diff\u00e9rence.<\/p>\n<p><strong>Les causes<\/strong><\/p>\n<p>Les situations rencontr\u00e9es sont nombreuses :<\/p>\n<ul>\n<li>meuble de cuisine plac\u00e9 devant le robinet ;<\/li>\n<li>chaudi\u00e8re enferm\u00e9e dans un caisson sans acc\u00e8s suffisant ;<\/li>\n<li>faux plafond masquant une vanne ;<\/li>\n<li>cloison ajout\u00e9e apr\u00e8s les travaux.<\/li>\n<\/ul>\n<p><strong>Comment \u00e9viter cette situation ?<\/strong><\/p>\n<p>Avant la pose des meubles :<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/2714.svg\" alt=\"\u2714\" \/> v\u00e9rifier l&rsquo;accessibilit\u00e9 de chaque robinet ;<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/2714.svg\" alt=\"\u2714\" \/> pr\u00e9voir une trappe de visite lorsque cela est n\u00e9cessaire ;<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/2714.svg\" alt=\"\u2714\" \/> informer le menuisier de la pr\u00e9sence des organes de coupure.<\/p>\n<p><strong>Conseil Inductance<\/strong><\/p>\n<p>Avant la r\u00e9ception du chantier, ouvrez et fermez chaque robinet.<\/p>\n<p>Si cette op\u00e9ration est difficile, le contr\u00f4leur rencontrera probablement la m\u00eame difficult\u00e9.<\/p>\n<p><strong>8.2 Ventilation insuffisante<\/strong><\/p>\n<p>Une mauvaise ventilation constitue une anomalie particuli\u00e8rement importante.<\/p>\n<p>Les appareils qui utilisent l&rsquo;air du local doivent disposer d&rsquo;une alimentation permanente en air.<\/p>\n<p>Une grille obtur\u00e9e peut avoir des cons\u00e9quences graves.<\/p>\n<p><strong>Les causes rencontr\u00e9es<\/strong><\/p>\n<p>Les occupants ferment parfois volontairement les grilles afin de :<\/p>\n<ul>\n<li>\u00e9viter les courants d&rsquo;air ;<\/li>\n<li>r\u00e9duire le bruit ;<\/li>\n<li>am\u00e9liorer l&rsquo;isolation.<\/li>\n<\/ul>\n<p>Cette pratique est dangereuse.<\/p>\n<p><strong>Les cons\u00e9quences<\/strong><\/p>\n<p>Une arriv\u00e9e d&rsquo;air insuffisante peut provoquer :<\/p>\n<ul>\n<li>une mauvaise combustion ;<\/li>\n<li>une augmentation du monoxyde de carbone ;<\/li>\n<li>un fonctionnement instable des appareils.<\/li>\n<\/ul>\n<p><strong>Cas r\u00e9el<\/strong><\/p>\n<p>Lors d&rsquo;une r\u00e9novation \u00e9nerg\u00e9tique, toutes les anciennes grilles de ventilation sont remplac\u00e9es par des panneaux isolants.<\/p>\n<p>Quelques semaines plus tard, la chaudi\u00e8re atmosph\u00e9rique fonctionne difficilement.<\/p>\n<p>Le contr\u00f4le r\u00e9v\u00e8le que l&rsquo;air de combustion est devenu insuffisant.<\/p>\n<p>Le probl\u00e8me dispara\u00eet imm\u00e9diatement apr\u00e8s le r\u00e9tablissement des ouvertures de ventilation.<\/p>\n<p><strong>8.3 Mauvais cheminement des conduites<\/strong><\/p>\n<p>Le r\u00e9seau de gaz doit rester simple, logique et facilement identifiable.<\/p>\n<p>Pourtant, certaines installations pr\u00e9sentent :<\/p>\n<ul>\n<li>des d\u00e9tours inutiles ;<\/li>\n<li>un nombre excessif de raccords ;<\/li>\n<li>des croisements complexes.<\/li>\n<\/ul>\n<p>Ces situations compliquent fortement les interventions futures.<\/p>\n<p><strong>Pourquoi est-ce un probl\u00e8me ?<\/strong><\/p>\n<p>Chaque raccord constitue un point potentiel de fuite.<\/p>\n<p>Un r\u00e9seau complexe est \u00e9galement plus difficile \u00e0 contr\u00f4ler.<\/p>\n<p><strong>Bonne pratique<\/strong><\/p>\n<p>Toujours privil\u00e9gier :<\/p>\n<ul>\n<li>le trajet le plus court ;<\/li>\n<li>le plus petit nombre de raccords ;<\/li>\n<li>un cheminement facilement visible.<\/li>\n<\/ul>\n<p><strong>8.4 Supports insuffisants<\/strong><\/p>\n<p>Une canalisation mal fix\u00e9e travaille davantage.<\/p>\n<p>Les vibrations peuvent progressivement solliciter les raccords.<\/p>\n<p>Une fixation correcte am\u00e9liore :<\/p>\n<ul>\n<li>la s\u00e9curit\u00e9 ;<\/li>\n<li>la durabilit\u00e9 ;<\/li>\n<li>l&rsquo;esth\u00e9tique de l&rsquo;installation.<\/li>\n<\/ul>\n<p><strong>Les d\u00e9fauts observ\u00e9s<\/strong><\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/274c.svg\" alt=\"\u274c\" \/> tuyauterie suspendue sans support ;<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/274c.svg\" alt=\"\u274c\" \/> collier manquant ;<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/274c.svg\" alt=\"\u274c\" \/> fixation desserr\u00e9e ;<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/274c.svg\" alt=\"\u274c\" \/> canalisation utilis\u00e9e comme support d&rsquo;autres \u00e9quipements.<\/p>\n<p><strong>8.5 Travers\u00e9es de murs non prot\u00e9g\u00e9es<\/strong><\/p>\n<p>Lorsqu&rsquo;une conduite traverse une paroi, elle peut \u00eatre soumise :<\/p>\n<ul>\n<li>aux mouvements du b\u00e2timent ;<\/li>\n<li>aux frottements ;<\/li>\n<li>aux contraintes m\u00e9caniques.<\/li>\n<\/ul>\n<p>Une protection adapt\u00e9e limite fortement ces risques.<\/p>\n<p><strong>Pourquoi cette protection est-elle importante ?<\/strong><\/p>\n<p>Une canalisation m\u00e9tallique en contact direct avec un mat\u00e9riau abrasif peut subir une usure progressive.<\/p>\n<p>M\u00eame si cette d\u00e9gradation est lente, elle doit \u00eatre \u00e9vit\u00e9e.<\/p>\n<p><strong>8.6 Non-respect des prescriptions du fabricant<\/strong><\/p>\n<p>Les fabricants consacrent plusieurs ann\u00e9es au d\u00e9veloppement de leurs appareils.<\/p>\n<p>Leurs notices pr\u00e9cisent :<\/p>\n<ul>\n<li>les longueurs maximales de conduits ;<\/li>\n<li>les diam\u00e8tres autoris\u00e9s ;<\/li>\n<li>les accessoires compatibles ;<\/li>\n<li>les distances minimales.<\/li>\n<\/ul>\n<p>Ces prescriptions font partie int\u00e9grante de l&rsquo;installation.<\/p>\n<p><strong>Les erreurs fr\u00e9quentes<\/strong><\/p>\n<p>Au cours des inspections, les contr\u00f4leurs rencontrent notamment :<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/274c.svg\" alt=\"\u274c\" \/> conduits rallong\u00e9s au-del\u00e0 des limites autoris\u00e9es ;<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/274c.svg\" alt=\"\u274c\" \/> accessoires provenant d&rsquo;un autre fabricant ;<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/274c.svg\" alt=\"\u274c\" \/> pente des conduits non conforme ;<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/274c.svg\" alt=\"\u274c\" \/> absence de certains \u00e9l\u00e9ments pr\u00e9vus par le constructeur.<\/p>\n<p><strong>Conseil Inductance<\/strong><\/p>\n<p>Avant toute installation, prenez quelques minutes pour relire la notice technique.<\/p>\n<p>Cette simple v\u00e9rification permet souvent d&rsquo;\u00e9viter plusieurs non-conformit\u00e9s.<\/p>\n<p><strong>8.7 Corrosion des canalisations<\/strong><\/p>\n<p>La corrosion appara\u00eet principalement dans les environnements humides.<\/p>\n<p>Elle peut \u00eatre acc\u00e9l\u00e9r\u00e9e par :<\/p>\n<ul>\n<li>des infiltrations d&rsquo;eau ;<\/li>\n<li>une mauvaise protection ;<\/li>\n<li>certains produits chimiques.<\/li>\n<\/ul>\n<p><strong>Les signes \u00e0 surveiller<\/strong><\/p>\n<ul>\n<li>peinture qui s&rsquo;\u00e9caille ;<\/li>\n<li>traces de rouille ;<\/li>\n<li>humidit\u00e9 persistante ;<\/li>\n<li>d\u00e9gradation des colliers.<\/li>\n<\/ul>\n<p>Une intervention pr\u00e9coce permet g\u00e9n\u00e9ralement d&rsquo;\u00e9viter des r\u00e9parations importantes.<\/p>\n<p><strong>Tableau r\u00e9capitulatif<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<td>\n<p><strong>Non-conformit\u00e9<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Cons\u00e9quence principale<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Comment l&rsquo;\u00e9viter<\/strong><\/p>\n<\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\n<p>Robinet inaccessible<\/p>\n<\/td>\n<td>\n<p>Coupure impossible en urgence<\/p>\n<\/td>\n<td>\n<p>Pr\u00e9voir l&rsquo;acc\u00e8s avant les finitions<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Ventilation obtur\u00e9e<\/p>\n<\/td>\n<td>\n<p>Mauvaise combustion<\/p>\n<\/td>\n<td>\n<p>Maintenir les ouvertures libres<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Trop de raccords<\/p>\n<\/td>\n<td>\n<p>Risque accru de fuite<\/p>\n<\/td>\n<td>\n<p>Simplifier le r\u00e9seau<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Supports insuffisants<\/p>\n<\/td>\n<td>\n<p>Contraintes m\u00e9caniques<\/p>\n<\/td>\n<td>\n<p>Installer des fixations adapt\u00e9es<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Travers\u00e9e non prot\u00e9g\u00e9e<\/p>\n<\/td>\n<td>\n<p>Usure de la conduite<\/p>\n<\/td>\n<td>\n<p>Pr\u00e9voir une protection m\u00e9canique<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Notice non respect\u00e9e<\/p>\n<\/td>\n<td>\n<p>Dysfonctionnement<\/p>\n<\/td>\n<td>\n<p>Suivre les prescriptions du fabricant<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Corrosion<\/p>\n<\/td>\n<td>\n<p>D\u00e9gradation progressive<\/p>\n<\/td>\n<td>\n<p>Prot\u00e9ger les canalisations<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Les cinq v\u00e9rifications avant de demander un contr\u00f4le<\/strong><\/p>\n<p>Chez Inductance, nous conseillons syst\u00e9matiquement aux installateurs de r\u00e9aliser cette derni\u00e8re v\u00e9rification.<\/p>\n<p><strong>Question n\u00b01<\/strong><\/p>\n<p>Puis-je couper rapidement le gaz sur chaque appareil ?<\/p>\n<p><strong>Question n\u00b02<\/strong><\/p>\n<p>Toutes les canalisations sont-elles correctement fix\u00e9es ?<\/p>\n<p><strong>Question n\u00b03<\/strong><\/p>\n<p>Les conduits d&rsquo;\u00e9vacuation sont-ils conformes aux prescriptions du fabricant ?<\/p>\n<p><strong>Question n\u00b04<\/strong><\/p>\n<p>Toutes les grilles de ventilation sont-elles pr\u00e9sentes et d\u00e9gag\u00e9es ?<\/p>\n<p><strong>Question n\u00b05<\/strong><\/p>\n<p>L&rsquo;installation est-elle propre et enti\u00e8rement termin\u00e9e ?<\/p>\n<p>Si la r\u00e9ponse est \u00ab oui \u00bb \u00e0 ces cinq questions, l&rsquo;installation est g\u00e9n\u00e9ralement pr\u00eate pour un contr\u00f4le.<\/p>\n<p><strong>L&rsquo;\u0153il du contr\u00f4leur Inductance<\/strong><\/p>\n<p>L&rsquo;exp\u00e9rience montre qu&rsquo;une installation bien r\u00e9alis\u00e9e est rarement celle qui utilise le mat\u00e9riel le plus co\u00fbteux.<\/p>\n<p>C&rsquo;est avant tout une installation o\u00f9 chaque d\u00e9tail a \u00e9t\u00e9 pens\u00e9 :<\/p>\n<ul>\n<li>un robinet accessible ;<\/li>\n<li>une canalisation bien align\u00e9e ;<\/li>\n<li>des supports correctement espac\u00e9s ;<\/li>\n<li>un conduit soigneusement mont\u00e9 ;<\/li>\n<li>une documentation compl\u00e8te.<\/li>\n<\/ul>\n<p>Cette rigueur refl\u00e8te le professionnalisme de l&rsquo;installateur et facilite le travail du contr\u00f4leur.<\/p>\n<p><strong>\u00c0 retenir<\/strong><\/p>\n<p>Les non-conformit\u00e9s les plus fr\u00e9quentes ne sont pas li\u00e9es \u00e0 des d\u00e9fauts complexes.<\/p>\n<p>Elles r\u00e9sultent souvent de petits oublis qui auraient pu \u00eatre corrig\u00e9s en quelques minutes avant le contr\u00f4le.<\/p>\n<p>Prendre le temps d&rsquo;inspecter son propre travail constitue la meilleure pr\u00e9paration \u00e0 une r\u00e9ception r\u00e9ussie.<\/p>\n<p><strong>Chapitre suivant<\/strong><\/p>\n<p>Dans le prochain chapitre, vous d\u00e9couvrirez <strong>la check-list compl\u00e8te d&rsquo;Inductance<\/strong>.<\/p>\n<p>Cette fiche pratique reprend, point par point, l&rsquo;ensemble des v\u00e9rifications qu&rsquo;un installateur peut effectuer avant de demander un contr\u00f4le.<\/p>\n<p>Elle pourra \u00eatre imprim\u00e9e et utilis\u00e9e directement sur chantier comme outil d&rsquo;autocontr\u00f4le.<\/p>\n<p><strong>Chapitre 9<\/strong><\/p>\n<p><strong>La check-list compl\u00e8te Inductance avant le contr\u00f4le<\/strong><\/p>\n<p><strong>Une installation bien pr\u00e9par\u00e9e est une installation qui se contr\u00f4le rapidement. Cette check-list permet \u00e0 l&rsquo;installateur d&rsquo;effectuer un v\u00e9ritable pr\u00e9-contr\u00f4le avant l&rsquo;arriv\u00e9e de l&rsquo;organisme agr\u00e9\u00e9.<\/strong><\/p>\n<p><strong>Introduction<\/strong><\/p>\n<p>La majorit\u00e9 des remarques formul\u00e9es lors des contr\u00f4les concerne des \u00e9l\u00e9ments facilement v\u00e9rifiables avant la visite.<\/p>\n<p>Quelques minutes d&rsquo;inspection permettent souvent d&rsquo;\u00e9viter :<\/p>\n<ul>\n<li>une contre-visite ;<\/li>\n<li>des d\u00e9placements suppl\u00e9mentaires ;<\/li>\n<li>des retards de chantier ;<\/li>\n<li>des co\u00fbts inutiles.<\/li>\n<\/ul>\n<p>Cette check-list reprend les principaux points que tout installateur devrait v\u00e9rifier avant de demander un contr\u00f4le.<\/p>\n<p>Elle peut \u00eatre utilis\u00e9e comme document de chantier ou int\u00e9gr\u00e9e \u00e0 votre proc\u00e9dure qualit\u00e9.<\/p>\n<p><strong>9.1 V\u00e9rification g\u00e9n\u00e9rale de l&rsquo;installation<\/strong><\/p>\n<p>Avant toute chose, observez l&rsquo;installation dans son ensemble.<\/p>\n<p>Posez-vous les questions suivantes.<\/p>\n<p><strong>L&rsquo;installation est-elle termin\u00e9e ?<\/strong><\/p>\n<p>\u25a1 Tous les appareils sont install\u00e9s.<\/p>\n<p>\u25a1 Toutes les canalisations sont fix\u00e9es.<\/p>\n<p>\u25a1 Tous les raccords sont termin\u00e9s.<\/p>\n<p>\u25a1 Aucun \u00e9l\u00e9ment provisoire n&rsquo;est encore pr\u00e9sent.<\/p>\n<p>\u25a1 Les finitions sont r\u00e9alis\u00e9es.<\/p>\n<p><strong>L&rsquo;installation est-elle propre ?<\/strong><\/p>\n<p>\u25a1 Aucun d\u00e9bris de chantier.<\/p>\n<p>\u25a1 Aucun mat\u00e9riau abandonn\u00e9.<\/p>\n<p>\u25a1 Les conduites sont propres.<\/p>\n<p>\u25a1 Les appareils sont accessibles.<\/p>\n<p>Une installation propre facilite toujours le contr\u00f4le.<\/p>\n<p><strong>9.2 V\u00e9rification des canalisations<\/strong><\/p>\n<p>Le r\u00e9seau doit \u00eatre examin\u00e9 dans son int\u00e9gralit\u00e9.<\/p>\n<p><strong>Cheminement<\/strong><\/p>\n<p>\u25a1 Les conduites suivent un trajet logique.<\/p>\n<p>\u25a1 Aucun d\u00e9tour inutile.<\/p>\n<p>\u25a1 Les canalisations restent identifiables.<\/p>\n<p>\u25a1 Aucun obstacle ne g\u00eane leur inspection.<\/p>\n<p><strong>Fixations<\/strong><\/p>\n<p>\u25a1 Tous les colliers sont pr\u00e9sents.<\/p>\n<p>\u25a1 Les fixations sont solides.<\/p>\n<p>\u25a1 Aucun tube ne pr\u00e9sente de mouvement.<\/p>\n<p>\u25a1 Les supports sont r\u00e9guli\u00e8rement r\u00e9partis.<\/p>\n<p><strong>Protection m\u00e9canique<\/strong><\/p>\n<p>\u25a1 Les travers\u00e9es de murs sont prot\u00e9g\u00e9es.<\/p>\n<p>\u25a1 Les canalisations ne risquent pas d&rsquo;\u00eatre endommag\u00e9es.<\/p>\n<p>\u25a1 Les conduites ext\u00e9rieures sont correctement prot\u00e9g\u00e9es.<\/p>\n<p><strong>Conseil Inductance<\/strong><\/p>\n<p>Prenez quelques minutes pour suivre visuellement toute la canalisation depuis le compteur jusqu&rsquo;au dernier appareil.<\/p>\n<p>Cette simple v\u00e9rification permet souvent de d\u00e9tecter imm\u00e9diatement une anomalie.<\/p>\n<p><strong>9.3 V\u00e9rification des robinets<\/strong><\/p>\n<p>Les organes de coupure doivent rester parfaitement accessibles.<\/p>\n<p>Contr\u00f4lez successivement :<\/p>\n<p>\u25a1 robinet g\u00e9n\u00e9ral ;<\/p>\n<p>\u25a1 robinets des appareils ;<\/p>\n<p>\u25a1 facilit\u00e9 de man\u0153uvre ;<\/p>\n<p>\u25a1 accessibilit\u00e9 compl\u00e8te.<\/p>\n<p>Aucun meuble ou habillage ne doit emp\u00eacher leur utilisation.<\/p>\n<p><strong>9.4 V\u00e9rification des appareils<\/strong><\/p>\n<p>Chaque appareil doit \u00eatre inspect\u00e9.<\/p>\n<p><strong>V\u00e9rifier<\/strong><\/p>\n<p>\u25a1 plaque signal\u00e9tique visible ;<\/p>\n<p>\u25a1 appareil correctement fix\u00e9 ;<\/p>\n<p>\u25a1 raccordement conforme ;<\/p>\n<p>\u25a1 alimentation gaz termin\u00e9e ;<\/p>\n<p>\u25a1 \u00e9vacuation raccord\u00e9e ;<\/p>\n<p>\u25a1 alimentation \u00e9lectrique pr\u00e9sente lorsque n\u00e9cessaire.<\/p>\n<p><strong>Documentation<\/strong><\/p>\n<p>La notice technique doit rester disponible.<\/p>\n<p>Elle facilite :<\/p>\n<ul>\n<li>les interventions futures ;<\/li>\n<li>la maintenance ;<\/li>\n<li>le contr\u00f4le.<\/li>\n<\/ul>\n<p><strong>9.5 V\u00e9rification des conduits<\/strong><\/p>\n<p>Les conduits repr\u00e9sentent un point essentiel du contr\u00f4le.<\/p>\n<p>V\u00e9rifiez notamment :<\/p>\n<p>\u25a1 bon mat\u00e9riau ;<\/p>\n<p>\u25a1 compatibilit\u00e9 avec l&rsquo;appareil ;<\/p>\n<p>\u25a1 embo\u00eetements complets ;<\/p>\n<p>\u25a1 joints pr\u00e9sents ;<\/p>\n<p>\u25a1 pente correcte ;<\/p>\n<p>\u25a1 supports suffisants ;<\/p>\n<p>\u25a1 sortie conforme.<\/p>\n<p><strong>Les condensats<\/strong><\/p>\n<p>Pour une chaudi\u00e8re \u00e0 condensation :<\/p>\n<p>\u25a1 siphon rempli ;<\/p>\n<p>\u25a1 \u00e9vacuation raccord\u00e9e ;<\/p>\n<p>\u25a1 \u00e9coulement libre.<\/p>\n<p><strong>9.6 V\u00e9rification de la ventilation<\/strong><\/p>\n<p>Selon le type d&rsquo;appareil install\u00e9 :<\/p>\n<p>\u25a1 grilles pr\u00e9sentes ;<\/p>\n<p>\u25a1 grilles non obstru\u00e9es ;<\/p>\n<p>\u25a1 circulation de l&rsquo;air possible ;<\/p>\n<p>\u25a1 aucune fermeture accidentelle.<\/p>\n<p>Les ouvertures de ventilation doivent rester permanentes lorsqu&rsquo;elles sont requises.<\/p>\n<p><strong>Cas pratique<\/strong><\/p>\n<p>Un installateur termine une nouvelle chaufferie.<\/p>\n<p>Tout semble conforme.<\/p>\n<p>Avant d&rsquo;appeler Inductance, il r\u00e9alise cette check-list.<\/p>\n<p>Il constate que :<\/p>\n<p>un simple carton de chantier bouche compl\u00e8tement une grille de ventilation.<\/p>\n<p>Sans cette v\u00e9rification, une non-conformit\u00e9 aurait \u00e9t\u00e9 constat\u00e9e.<\/p>\n<p>Quelques secondes suffisent \u00e0 corriger le probl\u00e8me.<\/p>\n<p><strong>9.7 V\u00e9rification des essais<\/strong><\/p>\n<p>Avant le contr\u00f4le officiel :<\/p>\n<p>\u25a1 essai d&rsquo;\u00e9tanch\u00e9it\u00e9 r\u00e9alis\u00e9 ;<\/p>\n<p>\u25a1 fonctionnement des appareils v\u00e9rifi\u00e9 ;<\/p>\n<p>\u25a1 absence d&rsquo;odeur de gaz ;<\/p>\n<p>\u25a1 pression contr\u00f4l\u00e9e ;<\/p>\n<p>\u25a1 aucun d\u00e9faut signal\u00e9 par les appareils.<\/p>\n<p>Ces essais rel\u00e8vent de la responsabilit\u00e9 de l&rsquo;installateur.<\/p>\n<p><strong>9.8 Les documents<\/strong><\/p>\n<p>Pr\u00e9parez :<\/p>\n<p>\u25a1 notices des appareils ;<\/p>\n<p>\u25a1 certificats \u00e9ventuels ;<\/p>\n<p>\u25a1 plans de l&rsquo;installation ;<\/p>\n<p>\u25a1 rapport des essais r\u00e9alis\u00e9s.<\/p>\n<p>Une documentation compl\u00e8te facilite toujours le contr\u00f4le.<\/p>\n<p><strong>Tableau r\u00e9capitulatif<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<td>\n<p><strong>\u00c9l\u00e9ment<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>V\u00e9rification<\/strong><\/p>\n<\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\n<p>Installation<\/p>\n<\/td>\n<td>\n<p>Termin\u00e9e<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Canalisations<\/p>\n<\/td>\n<td>\n<p>Correctement fix\u00e9es<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Robinets<\/p>\n<\/td>\n<td>\n<p>Accessibles<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Appareils<\/p>\n<\/td>\n<td>\n<p>Correctement raccord\u00e9s<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Conduits<\/p>\n<\/td>\n<td>\n<p>Conformes<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Ventilation<\/p>\n<\/td>\n<td>\n<p>Pr\u00e9sente<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Essais<\/p>\n<\/td>\n<td>\n<p>R\u00e9alis\u00e9s<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Documents<\/p>\n<\/td>\n<td>\n<p>Disponibles<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Les dix derni\u00e8res questions avant d&rsquo;appeler Inductance<\/strong><\/p>\n<p>Avant de demander un rendez-vous, posez-vous ces dix questions.<\/p>\n<p>\u25a1 L&rsquo;installation est-elle compl\u00e8tement termin\u00e9e ?<\/p>\n<p>\u25a1 Les conduites sont-elles correctement fix\u00e9es ?<\/p>\n<p>\u25a1 Tous les robinets sont-ils accessibles ?<\/p>\n<p>\u25a1 Les appareils correspondent-ils au projet ?<\/p>\n<p>\u25a1 Les conduits sont-ils compatibles ?<\/p>\n<p>\u25a1 Les notices du fabricant ont-elles \u00e9t\u00e9 respect\u00e9es ?<\/p>\n<p>\u25a1 Les ventilations sont-elles libres ?<\/p>\n<p>\u25a1 Les essais d&rsquo;\u00e9tanch\u00e9it\u00e9 ont-ils \u00e9t\u00e9 r\u00e9alis\u00e9s ?<\/p>\n<p>\u25a1 Les documents sont-ils pr\u00eats ?<\/p>\n<p>\u25a1 Seriez-vous pr\u00eat \u00e0 contr\u00f4ler cette installation si vous \u00e9tiez \u00e0 la place de l&rsquo;inspecteur ?<\/p>\n<p>Si la r\u00e9ponse est <strong>oui<\/strong> aux dix questions, l&rsquo;installation est g\u00e9n\u00e9ralement pr\u00eate \u00e0 \u00eatre contr\u00f4l\u00e9e.<\/p>\n<p><strong>Le conseil du contr\u00f4leur Inductance<\/strong><\/p>\n<p>Les meilleurs installateurs ne sont pas ceux qui ne commettent jamais d&rsquo;erreur.<\/p>\n<p>Ce sont ceux qui prennent le temps de v\u00e9rifier leur travail avant de demander un contr\u00f4le.<\/p>\n<p>Cette habitude permet :<\/p>\n<ul>\n<li>d&rsquo;am\u00e9liorer la qualit\u00e9 des installations ;<\/li>\n<li>de r\u00e9duire les contre-visites ;<\/li>\n<li>de renforcer la confiance des clients.<\/li>\n<\/ul>\n<p>Une check-list utilis\u00e9e syst\u00e9matiquement devient rapidement un r\u00e9flexe professionnel.<\/p>\n<p><strong>\u00c0 retenir<\/strong><\/p>\n<p>Cette check-list peut \u00eatre :<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/2714.svg\" alt=\"\u2714\" \/> imprim\u00e9e ;<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/2714.svg\" alt=\"\u2714\" \/> plastifi\u00e9e ;<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/2714.svg\" alt=\"\u2714\" \/> conserv\u00e9e dans le v\u00e9hicule de l&rsquo;installateur ;<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/2714.svg\" alt=\"\u2714\" \/> utilis\u00e9e sur chaque chantier.<\/p>\n<p>En quelques minutes, elle permet d&rsquo;\u00e9viter une grande partie des remarques les plus fr\u00e9quemment rencontr\u00e9es lors des contr\u00f4les.<\/p>\n<p><strong>Chapitre suivant<\/strong><\/p>\n<p>Dans le dernier chapitre, nous r\u00e9pondrons aux <strong>questions les plus fr\u00e9quemment pos\u00e9es aux contr\u00f4leurs d&rsquo;Inductance<\/strong>.<\/p>\n<p>Vous y trouverez des r\u00e9ponses simples et pr\u00e9cises concernant :<\/p>\n<ul>\n<li>les contr\u00f4les ;<\/li>\n<li>les chaudi\u00e8res ;<\/li>\n<li>les conduits ;<\/li>\n<li>les ventilations ;<\/li>\n<li>les obligations r\u00e9glementaires ;<\/li>\n<li>les bonnes pratiques \u00e0 adopter pour garantir une installation s\u00fbre et durable.<\/li>\n<\/ul>\n<p>Ce chapitre constituera une v\u00e9ritable <strong>FAQ pratique<\/strong>, directement inspir\u00e9e des questions pos\u00e9es quotidiennement par les installateurs et les particuliers.<\/p>\n<p><strong>Chapitre 10<\/strong><\/p>\n<p><strong>Les questions les plus fr\u00e9quemment pos\u00e9es \u00e0 Inductance (FAQ)<\/strong><\/p>\n<p><strong>Cette FAQ reprend les questions les plus souvent pos\u00e9es par les particuliers, les installateurs, les architectes et les gestionnaires de b\u00e2timents lors des contr\u00f4les r\u00e9alis\u00e9s par Inductance.<\/strong><\/p>\n<p><strong>Introduction<\/strong><\/p>\n<p>Au fil des ann\u00e9es, les contr\u00f4leurs d&rsquo;Inductance r\u00e9pondent quotidiennement \u00e0 de nombreuses questions.<\/p>\n<p>Certaines concernent la r\u00e9glementation.<\/p>\n<p>D&rsquo;autres portent sur les appareils, les conduits ou les responsabilit\u00e9s de chacun.<\/p>\n<p>Les r\u00e9ponses ci-dessous ont pour objectif de clarifier les situations les plus courantes.<\/p>\n<p>Chaque installation restant particuli\u00e8re, elles ne remplacent toutefois jamais l&rsquo;avis d&rsquo;un professionnel ou les prescriptions techniques applicables.<\/p>\n<p><strong>10.1 Questions g\u00e9n\u00e9rales<\/strong><\/p>\n<p><strong>Un contr\u00f4le est-il obligatoire ?<\/strong><\/p>\n<p>Selon la nature des travaux r\u00e9alis\u00e9s et les prescriptions applicables, un contr\u00f4le peut \u00eatre exig\u00e9 avant la mise en service ou apr\u00e8s une modification importante de l&rsquo;installation.<\/p>\n<p>En cas de doute, il est recommand\u00e9 de se renseigner avant le d\u00e9but des travaux.<\/p>\n<p><strong>Pourquoi faire contr\u00f4ler une installation qui fonctionne parfaitement ?<\/strong><\/p>\n<p>Une installation peut sembler fonctionner normalement tout en pr\u00e9sentant un d\u00e9faut de s\u00e9curit\u00e9.<\/p>\n<p>Le contr\u00f4le ne v\u00e9rifie pas uniquement le fonctionnement.<\/p>\n<p>Il examine \u00e9galement :<\/p>\n<ul>\n<li>la conformit\u00e9 de la pose ;<\/li>\n<li>la s\u00e9curit\u00e9 des occupants ;<\/li>\n<li>l&rsquo;accessibilit\u00e9 ;<\/li>\n<li>les dispositifs de protection.<\/li>\n<\/ul>\n<p><strong>Le contr\u00f4leur peut-il r\u00e9parer l&rsquo;installation ?<\/strong><\/p>\n<p>Non.<\/p>\n<p>Le contr\u00f4leur est totalement ind\u00e9pendant.<\/p>\n<p>Son r\u00f4le consiste uniquement \u00e0 constater l&rsquo;\u00e9tat de l&rsquo;installation.<\/p>\n<p>Les r\u00e9parations doivent \u00eatre r\u00e9alis\u00e9es par un installateur.<\/p>\n<p><strong>10.2 Questions sur les chaudi\u00e8res<\/strong><\/p>\n<p><strong>Puis-je remplacer moi-m\u00eame une chaudi\u00e8re ?<\/strong><\/p>\n<p>Le remplacement d&rsquo;une chaudi\u00e8re n\u00e9cessite des comp\u00e9tences techniques.<\/p>\n<p>Il implique notamment :<\/p>\n<ul>\n<li>le raccordement au gaz ;<\/li>\n<li>l&rsquo;\u00e9vacuation des fum\u00e9es ;<\/li>\n<li>l&rsquo;alimentation \u00e9lectrique ;<\/li>\n<li>les r\u00e9glages de combustion.<\/li>\n<\/ul>\n<p>Pour ces raisons, il est vivement conseill\u00e9 de faire appel \u00e0 un professionnel qualifi\u00e9.<\/p>\n<p><strong>Une chaudi\u00e8re \u00e0 condensation est-elle toujours le meilleur choix ?<\/strong><\/p>\n<p>Dans la majorit\u00e9 des habitations modernes, oui.<\/p>\n<p>Elle offre g\u00e9n\u00e9ralement :<\/p>\n<ul>\n<li>un excellent rendement ;<\/li>\n<li>une consommation r\u00e9duite ;<\/li>\n<li>des \u00e9missions de CO\u2082 plus faibles.<\/li>\n<\/ul>\n<p>Cependant, elle n\u00e9cessite un conduit compatible et une \u00e9vacuation correcte des condensats.<\/p>\n<p><strong>Peut-on conserver l&rsquo;ancien conduit de chemin\u00e9e ?<\/strong><\/p>\n<p>Pas syst\u00e9matiquement.<\/p>\n<p>Avant toute r\u00e9utilisation, il convient de v\u00e9rifier :<\/p>\n<ul>\n<li>sa compatibilit\u00e9 ;<\/li>\n<li>son \u00e9tat ;<\/li>\n<li>son diam\u00e8tre ;<\/li>\n<li>les prescriptions du fabricant de la chaudi\u00e8re.<\/li>\n<\/ul>\n<p><strong>10.3 Questions sur la ventilation<\/strong><\/p>\n<p><strong>Pourquoi une grille de ventilation ne peut-elle pas \u00eatre bouch\u00e9e ?<\/strong><\/p>\n<p>Certaines installations utilisent l&rsquo;air du local pour assurer la combustion.<\/p>\n<p>Supprimer cette arriv\u00e9e d&rsquo;air peut entra\u00eener :<\/p>\n<ul>\n<li>une mauvaise combustion ;<\/li>\n<li>la production de monoxyde de carbone ;<\/li>\n<li>un fonctionnement instable de l&rsquo;appareil.<\/li>\n<\/ul>\n<p>La ventilation constitue donc un \u00e9l\u00e9ment essentiel de la s\u00e9curit\u00e9.<\/p>\n<p><strong>Une VMC remplace-t-elle toujours une grille de ventilation ?<\/strong><\/p>\n<p>Pas n\u00e9cessairement.<\/p>\n<p>Chaque situation doit \u00eatre \u00e9tudi\u00e9e individuellement.<\/p>\n<p>Le fonctionnement du syst\u00e8me de ventilation doit \u00eatre compatible avec les exigences de l&rsquo;appareil install\u00e9.<\/p>\n<p><strong>10.4 Questions sur les conduits<\/strong><\/p>\n<p><strong>Pourquoi faut-il utiliser les accessoires du fabricant ?<\/strong><\/p>\n<p>Les conduits sont con\u00e7us comme un ensemble.<\/p>\n<p>Chaque \u00e9l\u00e9ment :<\/p>\n<ul>\n<li>joint ;<\/li>\n<li>coude ;<\/li>\n<li>rallonge ;<\/li>\n<li>terminal,<\/li>\n<\/ul>\n<p>fait partie d&rsquo;un syst\u00e8me certifi\u00e9.<\/p>\n<p>Le m\u00e9lange de composants provenant de fabricants diff\u00e9rents peut compromettre l&rsquo;\u00e9tanch\u00e9it\u00e9 ou les performances du conduit.<\/p>\n<p><strong>Les conduits doivent-ils \u00eatre entretenus ?<\/strong><\/p>\n<p>Oui.<\/p>\n<p>M\u00eame les conduits modernes doivent \u00eatre inspect\u00e9s r\u00e9guli\u00e8rement.<\/p>\n<p>L&rsquo;entretien permet notamment de v\u00e9rifier :<\/p>\n<ul>\n<li>leur \u00e9tat ;<\/li>\n<li>leur fixation ;<\/li>\n<li>l&rsquo;absence d&rsquo;obstruction.<\/li>\n<\/ul>\n<p><strong>10.5 Questions sur les tuyauteries<\/strong><\/p>\n<p><strong>Une canalisation peut-elle \u00eatre encastr\u00e9e ?<\/strong><\/p>\n<p>Certaines canalisations peuvent \u00eatre int\u00e9gr\u00e9es dans la construction sous r\u00e9serve du respect des prescriptions techniques applicables.<\/p>\n<p>Le choix d\u00e9pend notamment :<\/p>\n<ul>\n<li>du mat\u00e9riau utilis\u00e9 ;<\/li>\n<li>du mode de pose ;<\/li>\n<li>de l&rsquo;accessibilit\u00e9 future.<\/li>\n<\/ul>\n<p><strong>Pourquoi faut-il prot\u00e9ger les travers\u00e9es de murs ?<\/strong><\/p>\n<p>Une travers\u00e9e mal prot\u00e9g\u00e9e peut provoquer :<\/p>\n<ul>\n<li>une usure progressive ;<\/li>\n<li>des contraintes m\u00e9caniques ;<\/li>\n<li>une d\u00e9t\u00e9rioration de la canalisation.<\/li>\n<\/ul>\n<p>Une protection adapt\u00e9e am\u00e9liore consid\u00e9rablement la durabilit\u00e9 de l&rsquo;installation.<\/p>\n<p><strong>10.6 Questions sur les d\u00e9tecteurs<\/strong><\/p>\n<p><strong>Un d\u00e9tecteur de monoxyde de carbone est-il obligatoire ?<\/strong><\/p>\n<p>La r\u00e9glementation peut varier selon la R\u00e9gion et le contexte.<\/p>\n<p>M\u00eame lorsqu&rsquo;il n&rsquo;est pas impos\u00e9, son installation est fortement recommand\u00e9e.<\/p>\n<p>Le d\u00e9tecteur constitue une protection compl\u00e9mentaire.<\/p>\n<p>Il ne remplace jamais :<\/p>\n<ul>\n<li>une installation conforme ;<\/li>\n<li>un entretien r\u00e9gulier ;<\/li>\n<li>une bonne ventilation.<\/li>\n<\/ul>\n<p><strong>O\u00f9 installer un d\u00e9tecteur de CO ?<\/strong><\/p>\n<p>Le d\u00e9tecteur doit \u00eatre plac\u00e9 conform\u00e9ment aux recommandations du fabricant.<\/p>\n<p>En r\u00e8gle g\u00e9n\u00e9rale, il est conseill\u00e9 de l&rsquo;installer :<\/p>\n<ul>\n<li>\u00e0 proximit\u00e9 des appareils \u00e0 combustion ;<\/li>\n<li>dans les zones de circulation ;<\/li>\n<li>dans les espaces occup\u00e9s.<\/li>\n<\/ul>\n<p>\u00c9vitez les endroits soumis \u00e0 une humidit\u00e9 excessive ou \u00e0 des courants d&rsquo;air importants.<\/p>\n<p><strong>10.7 Questions sur l&rsquo;entretien<\/strong><\/p>\n<p><strong>Pourquoi entretenir une chaudi\u00e8re qui fonctionne correctement ?<\/strong><\/p>\n<p>Avec le temps :<\/p>\n<ul>\n<li>les br\u00fbleurs s&rsquo;encrassent ;<\/li>\n<li>les r\u00e9glages \u00e9voluent ;<\/li>\n<li>certains composants s&rsquo;usent.<\/li>\n<\/ul>\n<p>Un entretien r\u00e9gulier permet :<\/p>\n<ul>\n<li>d&rsquo;am\u00e9liorer le rendement ;<\/li>\n<li>de r\u00e9duire la consommation ;<\/li>\n<li>de prolonger la dur\u00e9e de vie de l&rsquo;appareil ;<\/li>\n<li>de maintenir un bon niveau de s\u00e9curit\u00e9.<\/li>\n<\/ul>\n<p><strong>Que se passe-t-il si l&rsquo;entretien est n\u00e9glig\u00e9 ?<\/strong><\/p>\n<p>Les cons\u00e9quences peuvent \u00eatre nombreuses :<\/p>\n<ul>\n<li>augmentation de la consommation de gaz ;<\/li>\n<li>\u00e9missions plus importantes ;<\/li>\n<li>risques accrus de panne ;<\/li>\n<li>combustion d\u00e9grad\u00e9e ;<\/li>\n<li>r\u00e9duction de la dur\u00e9e de vie de l&rsquo;installation.<\/li>\n<\/ul>\n<p><strong>Tableau pratique<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<td>\n<p><strong>Question<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>R\u00e9ponse courte<\/strong><\/p>\n<\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\n<p>Une installation fonctionne, faut-il la contr\u00f4ler ?<\/p>\n<\/td>\n<td>\n<p>Oui, la s\u00e9curit\u00e9 ne d\u00e9pend pas uniquement du fonctionnement.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Peut-on boucher une ventilation ?<\/p>\n<\/td>\n<td>\n<p>Non, jamais lorsqu&rsquo;elle est n\u00e9cessaire \u00e0 la combustion.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Peut-on m\u00e9langer plusieurs fabricants de conduits ?<\/p>\n<\/td>\n<td>\n<p>G\u00e9n\u00e9ralement non, sauf si cela est explicitement autoris\u00e9.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Une chaudi\u00e8re \u00e0 condensation n\u00e9cessite-t-elle un entretien ?<\/p>\n<\/td>\n<td>\n<p>Oui, comme tout appareil \u00e0 combustion.<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Un d\u00e9tecteur CO remplace-t-il un contr\u00f4le ?<\/p>\n<\/td>\n<td>\n<p>Non, il s&rsquo;agit d&rsquo;une protection compl\u00e9mentaire.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Les cinq conseils d&rsquo;Inductance<\/strong><\/p>\n<p>Apr\u00e8s plusieurs milliers de contr\u00f4les, cinq recommandations reviennent syst\u00e9matiquement.<\/p>\n<p><strong>Conseil n\u00b01<\/strong><\/p>\n<p>Ne modifiez jamais une installation sans v\u00e9rifier les cons\u00e9quences sur la s\u00e9curit\u00e9.<\/p>\n<p><strong>Conseil n\u00b02<\/strong><\/p>\n<p>Conservez toujours les notices techniques des appareils.<\/p>\n<p><strong>Conseil n\u00b03<\/strong><\/p>\n<p>Faites r\u00e9aliser les entretiens dans les d\u00e9lais recommand\u00e9s.<\/p>\n<p><strong>Conseil n\u00b04<\/strong><\/p>\n<p>N&rsquo;attendez jamais qu&rsquo;une panne survienne pour faire v\u00e9rifier votre installation.<\/p>\n<p><strong>Conseil n\u00b05<\/strong><\/p>\n<p>En cas de doute, demandez conseil avant de commencer les travaux.<\/p>\n<p>Une simple question pos\u00e9e au bon moment permet souvent d&rsquo;\u00e9viter des r\u00e9parations co\u00fbteuses.<\/p>\n<p><strong>Conclusion g\u00e9n\u00e9rale<\/strong><\/p>\n<p>Le gaz naturel est une \u00e9nergie performante, \u00e9conomique et particuli\u00e8rement s\u00fbre lorsqu&rsquo;il est utilis\u00e9 dans une installation conforme.<\/p>\n<p>La s\u00e9curit\u00e9 repose sur quatre principes essentiels :<\/p>\n<ul>\n<li>une conception correcte ;<\/li>\n<li>une installation r\u00e9alis\u00e9e dans les r\u00e8gles de l&rsquo;art ;<\/li>\n<li>un entretien r\u00e9gulier ;<\/li>\n<li>un contr\u00f4le ind\u00e9pendant.<\/li>\n<\/ul>\n<p>Ce guide a \u00e9t\u00e9 con\u00e7u pour vous aider \u00e0 mieux comprendre ces principes et \u00e0 pr\u00e9parer efficacement vos projets.<\/p>\n<p>Chez <strong>Inductance<\/strong>, nous sommes convaincus que la pr\u00e9vention reste le meilleur moyen d&rsquo;assurer la s\u00e9curit\u00e9 des personnes et la qualit\u00e9 des installations.<\/p>\n<p>Notre mission ne se limite pas \u00e0 v\u00e9rifier une installation.<\/p>\n<p>Elle consiste \u00e9galement \u00e0 informer, conseiller et accompagner les professionnels comme les particuliers vers des installations toujours plus s\u00fbres, performantes et durables.<\/p>\n<p><strong>\u00c0 propos d&rsquo;Inductance<\/strong><\/p>\n<p><strong>Inductance<\/strong> est un organisme sp\u00e9cialis\u00e9 dans les contr\u00f4les techniques et la performance \u00e9nerg\u00e9tique des b\u00e2timents.<\/p>\n<p>Nos domaines d&rsquo;expertise comprennent notamment :<\/p>\n<ul>\n<li>Contr\u00f4les des installations au gaz<\/li>\n<li>Contr\u00f4les des installations \u00e9lectriques<\/li>\n<li>Certificats PEB<\/li>\n<li>Audits \u00e9nerg\u00e9tiques<\/li>\n<li>Conseils techniques<\/li>\n<li>Expertise des b\u00e2timents<\/li>\n<li>Accompagnement des professionnels<\/li>\n<\/ul>\n<p>Notre \u00e9quipe met son exp\u00e9rience au service de la s\u00e9curit\u00e9, de la qualit\u00e9 et de la conformit\u00e9 de vos installations.<\/p>\n<p>Pour plus d&rsquo;informations ou pour prendre rendez-vous :<\/p>\n<p><strong>INDUCTANCE<\/strong><\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/1f4cd.svg\" alt=\"\ud83d\udccd\" \/> Belgique<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/1f310.svg\" alt=\"\ud83c\udf10\" \/> <a href=\"https:\/\/inductance.be\/nl\/\"><em>www.inductance.be<\/em><\/a><\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/1f4e7.svg\" alt=\"\ud83d\udce7\" \/> info@inductance.be<\/p>\n<p><img decoding=\"async\" class=\"emoji\" role=\"img\" draggable=\"false\" src=\"https:\/\/s.w.org\/images\/core\/emoji\/17.0.2\/svg\/1f4de.svg\" alt=\"\ud83d\udcde\" \/> 081 835944<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Le contr\u00f4le d&rsquo;une installation gaz par un organisme agr\u00e9\u00e9\u00a0ne doit pas \u00eatre consid\u00e9r\u00e9 comme une sanction, mais comme la derni\u00e8re [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"elementor_theme","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[18],"tags":[20],"class_list":["post-2906","post","type-post","status-publish","format-standard","hentry","category-blog","tag-test1"],"_links":{"self":[{"href":"https:\/\/inductance.be\/nl\/wp-json\/wp\/v2\/posts\/2906","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/inductance.be\/nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/inductance.be\/nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/inductance.be\/nl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/inductance.be\/nl\/wp-json\/wp\/v2\/comments?post=2906"}],"version-history":[{"count":4,"href":"https:\/\/inductance.be\/nl\/wp-json\/wp\/v2\/posts\/2906\/revisions"}],"predecessor-version":[{"id":2910,"href":"https:\/\/inductance.be\/nl\/wp-json\/wp\/v2\/posts\/2906\/revisions\/2910"}],"wp:attachment":[{"href":"https:\/\/inductance.be\/nl\/wp-json\/wp\/v2\/media?parent=2906"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/inductance.be\/nl\/wp-json\/wp\/v2\/categories?post=2906"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/inductance.be\/nl\/wp-json\/wp\/v2\/tags?post=2906"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}